afacerilemn/woodbusinessportal

Hand split shingle traditional 5 layers - Demands and Offers for wood and wood products.

WoodBusinessPortal.com > Demands-Offers > Id 334512
Demands-Offers Demands-Offers

24 September 2020
Member authentication
UserUser
PasswordPassword
no password?
Company contact data Locate on map Images
Hand split shingle traditional 5 layers Hand split shingle traditional 5 layers
Bucuresti%2CRomania
You can use the following languages for the commercial correspondence:
Romana - English - Italiano - Français -

Sell

Hand split shingle traditional 5 layers

ID 334512 For the 5 layers (standard dimensions of l/L/w 85/330/5 mm)

It could be made from white fir and from spruce.

We call it the traditional patern.

Each shingle demands a minimum of 8 passings with ‘cutitoaia’ (a metal blade with handles) to become a finite material. These procedures are done at the hand-split shingle horse.

The hand-split shingle forms which are required for laying a ridge are as follows: the camp shingle, the crest shingle, the overhang shingle and the valley shingle.

The forms can be mounted with stainless steel or double galvanised nails (with hidden nail) on a board surface, laid-down with breaks of 4 cm lenght. This spacing between the support boards ensures good ventilation of the shingle, while having a role for the construction in case of tying the mounting platform (the shingleman seat). Under shingle’s support board surface there is a minimum 5 cm of layer left for ventilating the cover. By employing the shingle to ridges with specific slopes, this support board is in fact the shingle’s revetment as well. This sistem doesn`t need under layer for waterproof for roof angle more than 30 degree.

The shingle is treated in special pools in a traditional technique recommended by more tha 100 years old shingle roof that are still working. At the end of the placement a wax-based drench in different shades is applied. This final treatment will be performed only for design reason. In order to ease the performing of treatment by climber teams, brackets for bracing up their special equipment are provided.

The small dormer-windows with long connections are still used for ventilation as well as for protecting the brackets of the climbers. The big dormer-windows with short connections which are present on the big slopes of the ridge and create a specific architecture are feasible only with this type of shingle. This is a way of creating a dialogue between the hand-split shingle and the architecture it generates.

The price is refering to 1 sqm and is including the shingle,the treatment,and the implementation.

For the 5 layers (standard dimensions of l/L/w 85/330/5 mm)

It could be made from white fir and from spruce.

We call it the traditional patern.

Each shingle demands a minimum of 8 passings with ‘cutitoaia’ (a metal blade with handles) to become a finite material. These procedures are done at the hand-split shingle horse.

The hand-split shingle forms which are required for laying a ridge are as follows: the camp shingle, the crest shingle, the overhang shingle and the valley shingle.

The forms can be mounted with stainless steel or double galvanised nails (with hidden nail) on a board surface, laid-down with breaks of 4 cm lenght. This spacing between the support boards ensures good ventilation of the shingle, while having a role for the construction in case of tying the mounting platform (the shingleman seat). Under shingle’s support board surface there is a minimum 5 cm of layer left for ventilating the cover. By employing the shingle to ridges with specific slopes, this support board is in fact the shingle’s revetment as well. This sistem doesn`t need under layer for waterproof for roof angle more than 30 degree.

The shingle is treated in special pools in a traditional technique recommended by more tha 100 years old shingle roof that are still working. At the end of the placement a wax-based drench in different shades is applied. This final treatment will be performed only for design reason. In order to ease the performing of treatment by climber teams, brackets for bracing up their special equipment are provided.

The small dormer-windows with long connections are still used for ventilation as well as for protecting the brackets of the climbers. The big dormer-windows with short connections which are present on the big slopes of the ridge and create a specific architecture are feasible only with this type of shingle. This is a way of creating a dialogue between the hand-split shingle and the architecture it generates.

The price is refering to 1 sqm and is including the shingle,the treatment,and the implementation.

Hand split shingle traditional 5 layers
Quantity Units Delivery Incoterms
1 m2 EXW
Price Currency Delivery frequency
40 EURO based on mutual agreement
Hand split shingle traditional 5 layers Hand split shingle traditional 5 layers
Hand split shingle traditional 5 layers
Published on 2014-11-18
Expires on 2014-12-18
Send a message to this company
Your message ( please send only text message; in order to avoid spams the messages written in html code will not be sent)
Send message
safe trade